Customization: | Available |
---|---|
After-sales Service: | 12 Months Warranty & Life-Time Sale Service |
Warranty: | 1-Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
This system can provide CC mode, CV mode, CCCV mode, Pulse mode, CP mode, CR mode, DCIR mode, and HPPC etc. Through the work step editor, they can be edited to work in a combined work mode and can be quickly switched on the user's requirements. Through these basic functions, the test system can carry out battery performance testing, rate charge and discharge testing, capacity testing, cycle life testing, DC internal resistance testing, reliability testing, energy efficiency testing, simulated road condition testing, etc. When the same device works with multiple channels, the channels are completely independent of each other; when there is a need to expand the current, the channels can be connected in parallel.
AC Input Parameters
Item | Technical Parameters |
Wiring Method | AC380V Three-Phase Five-Wire System |
Input Power Supply | AC380V |
Power Factor | ≥99%(full load) |
THDi | ≤5%(full load) |
Maximum feedback efficiency | ≥92%(full load) |
Item | Technical Parameters |
Voltage range | Charging Voltage: 0V ~ 120V(customized) Discharging Voltage: 1V ~ 120V(customized) |
Voltage Accuracy | ±0.05%FS |
Voltage Resolution | 1mV |
Current Range | 0 ~ 100A (customized) |
Current Accuracy | ±0.05%FS |
Current Resolution | 1mA |
Current Response Time | 10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time | 20ms(-90%FS ~ 90%FS) |
Channel Control Mode | All channels can be independently controlled. |
Auxiliary channels | Each channel is equipped with an auxiliary temperature channel. |
Item | Technical Parameters |
Minimum Data Logging Time | 10ms |
Editable Number of Steps | 2000 |
Number of Step Cycles | 65535 |
Step Cycle Nesting | 5 |
Charge and Discharge Modes | Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria | Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types | Jump, Pause, Protect, Next Step |
Importing DBC Files | Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) | Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods | Export data in Excel and CSV formats. |
Item | Technical Parameters |
AC-Side Protection | AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection | Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection | Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating | IP22 |
Operating Temperature Range | 0ºC~ 45ºC |
Cooling Method | Forced Air Cooling |
Sound Level | ≤75dB |
1.BMS free docking development