Product Description
Introducing our 60V30A Battery Module Charge Energy Testing System, a solution designed to meticulously assess the charge energy performance of battery modules. This advanced testing system is tailored to meet the evolving demands of industries relying on reliable and efficient battery technology.
This testing system is tailored for industries engaged in the development, manufacturing, and quality control of battery modules. It finds application in electric vehicles, renewable energy storage systems, and various other sectors requiring robust and efficient battery technologies.
Product Features
High Precision Testing: The system excels in high-precision testing, providing accurate measurements critical for evaluating the charge energy capabilities of battery modules with a voltage rating of 60V and a current capacity of 30A.
Versatile Testing Modes: With versatile testing capabilities, the system supports various modes including constant current charge, ensuring adaptability to different testing requirements and scenarios.
Efficient Charge Energy Assessment: Specifically engineered for evaluating charge energy, the system delivers comprehensive insights into the efficiency and reliability of battery modules, contributing to improved performance and longevity.
User-Friendly Interface: The testing system is designed with a user-centric interface, promoting ease of operation. The intuitive controls and display facilitate a straightforward testing process, enhancing user convenience.
Safety Protocols: Prioritizing safety, the system incorporates multiple protective features, including safeguards against overcharge, over-discharge, and over-current. These mechanisms ensure a secure testing environment and safeguard both the equipment and the battery modules.
Product Parameters
AC Input Parameters
Item |
Technical Parameters |
Wiring Method |
AC220V Three-Phase Five-Wire System |
Input Power Supply |
AC220V |
Power Factor |
≥99%(full load) |
THDi |
≤5%(full load) |
Maximum feedback efficiency |
≥92%(full load) |
DC output parameters
Item |
Technical Parameters |
Voltage range |
Charging Voltage: 0V ~ 60V Discharging Voltage: 6V ~ 60V |
Voltage Accuracy |
±0.05%FS |
Voltage Resolution |
1mV |
Current Range |
0 ~ 20A |
Current Accuracy |
±0.05%FS |
Current Resolution |
1mA |
Current Response Time |
10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time |
20ms(-90%FS ~ 90%FS) |
Channel Control Mode |
All channels can be independently controlled. |
Auxiliary channels |
Each channel is equipped with an auxiliary temperature channel. |
Step Function Features / Function Features of Operation Steps
Item |
Technical Parameters |
Minimum Data Logging Time |
10ms |
Editable Number of Steps |
2000 |
Number of Step Cycles |
65535 |
Step Cycle Nesting |
5 |
Charge and Discharge Modes |
Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria |
Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types |
Jump, Pause, Protect, Next Step |
Importing DBC Files |
Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) |
Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods |
Export data in Excel and CSV formats. |
Protection Functions
Item |
Technical Parameters |
AC-Side Protection |
AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection |
Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection |
Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating |
IP22 |
Operating Temperature Range |
0ºC~ 45ºC |
Cooling Method |
Forced Air Cooling |
Sound Level |
≤75dB |
Usage Guidelines:
Voltage Configuration: Set the appropriate voltage parameters in accordance with the specifications of the battery modules under examination, ensuring accurate and relevant testing conditions.
Current Adjustment: Configure the current settings to align with the targeted testing objectives, ensuring that the system delivers precise measurements during the charge energy assessments.
Data Analysis: Utilize the system's high-precision measurements for thorough data analysis, gaining valuable insights into the charge energy performance of the battery modules.
Safety Precautions: Before initiating testing, ensure that the safety protocols, including overcharge, over-discharge, and over-current protection, are activated to maintain a secure testing environment.
Routine Maintenance: Perform regular checks and maintenance to guarantee the ongoing accuracy and reliability of the testing system, particularly when dealing with diverse battery module specifications.
Our 60V30A Battery Module Charge Energy Testing System stands as an advanced and indispensable tool, empowering industries to assess and enhance the charge energy capabilities of battery modules for a myriad of applications.