System Overview:
Introducing our cutting-edge 100V 30A Automotive Battery Pack Testing System, designed for ongoing charge and discharge testing of automotive battery packs. This sophisticated system ensures real-time evaluations of battery performance, offering a comprehensive solution for automotive applications.
Key Features:
High Voltage and Amperage Capability: With a capacity of 100V and 120A, this system accommodates the high voltage and current demands of automotive battery packs, providing robust testing capabilities.
Continuous Charging and Discharging: The system is perpetually engaged in charging and discharging activities, allowing for continuous real-time monitoring of automotive battery pack behavior under various conditions.
Dynamic Automotive Applications: Tailored for automotive use, the system offers dynamic testing scenarios, ensuring that automotive battery packs are evaluated in a manner that mirrors real-world driving conditions.
Versatile Testing Solution: Ideal for automotive manufacturers, research and development laboratories, and electric vehicle producers, this testing system provides a versatile solution for ongoing evaluations of automotive battery pack performance.
Product Parameters
Our devices come in different sizes and can be adjusted according to customer needs. The number of channels can also be customized; The following images and parameters are for reference only. Please refer to the actual confirmed ones
AC Input Parameters
Item |
Technical Parameters |
Wiring Method |
AC380V Three-Phase Five-Wire System |
Input Power Supply |
AC380V |
Power Factor |
≥99%(full load) |
THDi |
≤5%(full load) |
Maximum feedback efficiency |
≥92%(full load) |
DC output parameters
Item |
Technical Parameters |
Voltage range |
Charging Voltage: 0V ~ 100V Discharging Voltage: 6V ~ 100V |
Voltage Accuracy |
±0.05%FS |
Voltage Resolution |
1mV |
Current Range |
-30A~ 30A |
Current Accuracy |
±0.05%FS |
Current Resolution |
1mA |
Current Response Time |
10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time |
20ms(-90%FS ~ 90%FS) |
Channel Control Mode |
All channels can be independently controlled. |
Auxiliary channels |
Each channel is equipped with an auxiliary temperature channel. |
Step Function Features / Function Features of Operation Steps
Item |
Technical Parameters |
Minimum Data Logging Time |
10ms |
Editable Number of Steps |
2000 |
Number of Step Cycles |
65535 |
Step Cycle Nesting |
5 |
Charge and Discharge Modes |
Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria |
Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types |
Jump, Pause, Protect, Next Step |
Importing DBC Files |
Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) |
Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods |
Export data in Excel and CSV formats. |
Protection Functions
Item |
Technical Parameters |
AC-Side Protection |
AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection |
Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection |
Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating |
IP22 |
Operating Temperature Range |
0ºC~ 45ºC |
Cooling Method |
Forced Air Cooling |
Sound Level |
≤75dB |
Our Team
Certifications