Customization: | Available |
---|---|
After-sales Service: | 12 Months Warranty & Life-Time Sale Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
AC input parameters | Input power supply | AC 380V±10% 50/60±5Hz |
Power factor | ≥99%(full load) | |
THDI | ≤5%(full load) | |
Input impedance | ≥1 MΩ | |
Feedback efficiency | ≥92%(full load) | |
DC output parameters | Voltage range | Charging Voltage: 0V ~ 100V Discharging Voltage: 6V ~ 100V |
Voltage Accuracy | ±0.05%FS | |
Voltage Resolution | 1mV | |
Current Range | 0 ~ 100A | |
Current Accuracy | ±0.05%FS | |
Current Resolution | 1mA | |
Current Response Time | 10ms(10%FS ~ 90%FS) | |
Charge/Discharge Conversion Time | 20ms(-90%FS ~ 90%FS) | |
Channel Control Mode | All channels can be independently controlled. | |
Auxiliary channels | Each channel is equipped with an auxiliary temperature channel. | |
Working step functional characteristics | Support experimental testing | Battery cycle life test, battery capacity test, battery charge/discharge characteristic test, battery charge retention test, battery charge and discharge efficiency test, battery charge and discharge endurance test. |
Minimum recording time of data | 10ms | |
Number of steps | 2000 | |
Cycles | 65535 | |
Cyclic nesting | 5 | |
Charge-discharge mode | Standing, pausing, constant current charging CC, constant voltage charging CV, constant resistance charging CR, constant current and constant voltage charging CCCV, constant power charging CP, constant current discharging DC, constant power discharging DP, constant resistance discharging DR, DC internal resistance test (DCIR). | |
Cut-off condition | Voltage, current, capacity, energy, time, power, cycle times, BMS parameters, user-defined advanced parameters (supporting one or more logical AND or combinations). | |
Type of execution action | Jump, Pause, Protect, Next | |
485/DBC file import | Support file editing, saving and importing, 485/CA for each channel. | |
DC internal resistance test (DCIR) | It supports DCIR step and hardware real-time calculation, and supports (V1-V2)/(I1-I2) and (v1-v2)/I. | |
Data export mode | Excel and CSV format export | |
Defencive function | AC side protection | Power grid voltage over/under-voltage protection, surge protection, islanding protection, over/under-frequency protection, hardware over-temperature protection and self-detection protection, etc. |
DC side protection | Bus overvoltage and undervoltage protection, hardware overtemperature protection, battery channel line reverse connection protection, etc. | |
Battery side comprehensive protection | Upper and lower limits of total battery voltage, upper and lower limits of single battery voltage, upper and lower limits of battery temperature, upper and lower limits of battery charging and discharging current, upper and lower limits of battery capacity, BMS communication drop protection, network drop protection, etc. | |
Power failure data protection | It has the function of memory power failure protection, which can effectively avoid data loss caused by power failure or continue to run at the process breakpoint without modifying the process after incoming call. | |
Protection grades | IP20 | |
Operating temperature range | 0ºC-45ºC | |
Cooling mode | Forced cold air | |
Noise level | ≤80dB |
1.BMS free docking development
2. Accuracy 0.05%
3. Charge and discharge efficiency 92%
4. Avant-garde voltage protection below 60v, without a protection board, our software can predict 7 volts in advance
5. Our chassis appearance design is exquisite, small, in line with the optimal solution to heat dissipation effect, while using Delta fan, IGBT Infineon, the best configuration to ensure heat dissipation effect