Dc output parameter | ||
1.Channel | channels | 2 |
Single channel power | 3KW | |
Total output power | 6KW | |
2.Voltage | Range | Charging:0V ~ 100V; discharging:6V ~ 100V |
Accuracy | ±0.05%FS | |
Resolution | 1mV | |
3.Current | Range | -30A ~ 30A |
Accuracy | ±0.05%FS | |
Resolution | 1MA | |
4.The time | Current response time | 5ms(10%FS ~ 90%FS) |
conversion time | Charging&discharging:10ms(-90%FS ~ 90%FS) | |
5.Channel control mode |
All channels can be controlled independently | |
6.Dc internal resistance test | Current, power can edit 2 sections of current, running time, sampling time, cycle times, support custom DCIR calculation | |
7.Impulse testing | Support mode | Constant current/power charging and discharging |
Minimum pulse width | 50ms | |
8.Condition simulation test | Peak working steps | No limit |
Minimum pulse width | 50ms |
This Battery Tester is mainly used for lithium battery charging and discharging cycle test. The test items include battery charging protection voltage, discharging protection voltage, capacity, Temperature, internal resistance ,etc. The equipment has four test steps: charging, discharging, shelving and cycling.
Comprehensive Lithium Battery Testing: This system specializes in Lithium battery testing, offering a thorough analysis of key parameters to guarantee optimal functionality and longevity.AC Input Parameters
Item | Technical Parameters |
Wiring Method | AC380V Three-Phase Five-Wire System |
Input Power Supply | AC380V |
Power Factor | ≥99%(full load) |
THDi | ≤5%(full load) |
Maximum feedback efficiency | ≥92%(full load) |
Item | Technical Parameters |
Minimum Data Logging Time | 10ms |
Editable Number of Steps | 2000 |
Number of Step Cycles | 65535 |
Step Cycle Nesting | 5 |
Charge and Discharge Modes | Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria | Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types | Jump, Pause, Protect, Next Step |
Importing DBC Files | Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) | Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods | Export data in Excel and CSV formats. |
Item | Technical Parameters |
AC-Side Protection | AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection | Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection | Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating | IP22 |
Operating Temperature Range | 0ºC~ 45ºC |
Cooling Method | Forced Air Cooling |
Sound Level | ≤75dB |