Technical Specification | |||
Model number | HD-6U60V30A-08CH | ||
Environmental condition |
|||
1,Temperature | Operating temperature range | 0ºC ~ 45ºC | |
Storage temperature range | -10ºC ~ 50ºC | ||
2,Humidity | Operating humidity range | ≤70%RH(Vapourless condensation) | |
Storage humdity range | ≤95%RH(Vapourless condensation) | ||
Ac input parameter | |||
1,Input power supply | AC380V±15% 50/60±5Hz | ||
2,Power factor | ≥99%(Full load) | ||
3,Total Harmonic Current Distortion | THDI | ≤5%(Full load) | |
4,Input impedance | ≥1MΩ | ||
5,Input power | 15.7KW | ||
6,Overallefficiency (Max) | ≥92%(Full load) | ||
7,Noise | ≤75dB | ||
8,Cooling mode | Forced air cooling | ||
9,level of protection | IP20 | ||
Dc output parameter | |||
1.Channel | channels | 8 | |
Singlechannelpower | 1.8KW | ||
Total output power | 14.4KW | ||
2,Voltage | Range | Charging:0V ~ 60V; discharging:6V ~ 60V | |
Accuracy | ±0.05%FS | ||
Resolution | 1mV | ||
3,Current | Range | -30A ~ 30A | |
Accuracy | ±0.05%FS | ||
Resolution | 1MA | ||
4,The time | Current response time | 5ms(10%FS ~ 90%FS) | |
conversion time | Charging &discharging : 10ms(-90%FS ~ 90%FS) | ||
5,Channel control mode | All channels can be controlled independently | ||
6,Dc internal resistance test |
Current, power can edit 2 sections of current, running time, sampling time, cycle times, support custom DCIR calculation | ||
7,Impulse testing | Support mode | Constant current/power charging and discharging | |
Minimum pulse width | 50ms | ||
8,Condition simulation test | Peak working steps | No limit | |
Minimum pulse width | 50ms |