Feature
The aging cabinet is mainly used for testing the charging and discharging cycle of finished lithium batteries. The testing items include: battery charging protection voltage, discharging protection voltage, capacity, etc. The equipment has charging, discharging, shelving, and cycling four testing steps. The battery can be tested according to the set process by editing the corresponding steps.
Advantages
1. Single Point Control Technology
2. Each channel is independent of each other.
3. Anti-backup protection function
4. Automatic real-time data preservation
5. Two communication modes: serial port and network
electric bike Lithium Battery Analyzer Battery Testing System
AC Input Parameters
Item | Technical Parameters |
Wiring Method | AC380V Three-Phase Five-Wire System |
Input Power Supply | AC380V |
Power Factor | ≥99%(full load) |
THDi | ≤5%(full load) |
Maximum feedback efficiency | ≥92%(full load) |
1.Channel | channels | 4 |
Single channel power | 10KW | |
Total output power | 40KW | |
2.Voltage | Range | Charging:0V -100V; discharging:6V ~ 100V |
Accuracy | ±0.05%FS | |
Resolution | 1mV | |
3.Current | Range | -100A ~ 100A |
Accuracy | ±0.05%FS | |
Resolution | 1MA | |
4.The time | Current response time | 10ms(10%FS ~ 90%FS) |
conversion time | Charging&discharging:20ms(-90%FS ~ 90%FS) | |
5.Channel control mode |
All channels can be controlled independently | |
6. DC side protection | Bus overvoltage and undervoltage protection, hardware over temperature protection, battery channel line reverse connection protection, etc | |
7.Communication type | upper computer | the upper computer is based on TCP/IP protocol |
Interface: | Ethernet, CAN, 485;Support DBC import | |
8. Data method | export method | Export in Excel and CSV formats |
Viewing | Tree expansion and contraction viewing |
Item | Technical Parameters |
Minimum Data Logging Time | 10ms |
Editable Number of Steps | 2000 |
Number of Step Cycles | 65535 |
Step Cycle Nesting | 5 |
Charge and Discharge Modes | Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria | Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types | Jump, Pause, Protect, Next Step |
Importing DBC Files | Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) | Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods | Export data in Excel and CSV formats. |
Item | Technical Parameters |
AC-Side Protection | AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection | Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection | Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating | IP22 |
Operating Temperature Range | 0ºC~ 45ºC |
Cooling Method | Forced Air Cooling |
Sound Level | ≤75dB |
Shenzhen Hongda New Energy Co., Ltd. was founded in 2014, It is a leading and professional manufacturer of battery test system,providing comprehensive battery testing and automation solutions, as well as EV charger and BESS solutions. We are working on uncompromising quality, accuracy,responsibility,innovation, reliability and long operational life duration.
1;Factory direct price with good quality battery testing equipment
2; Nice quality
3;OEM/ODM service
4;After sales service 24/7