Product Description
Introducing our cutting-edge Battery Testing System designed for applications requiring precise testing of batteries within the voltage and current specifications of 30V and 60A, respectively. This advanced system boasts 8 channels, providing a comprehensive solution for simultaneous testing of multiple batteries.
Product Key Features:
Versatile Testing Capability: The Battery Testing System is specifically engineered for applications requiring testing within the parameters of 30V and 60A, making it suitable for a diverse range of batteries.
Multi-Channel Efficiency: With 8 channels, this system enables efficient and simultaneous testing of multiple batteries, optimizing throughput and streamlining testing processes.
Precision Analysis: Our testing system ensures precision in assessing key battery parameters, including capacity, cycle life, and performance under various charging and discharging conditions.
Wide Applicability: Tailored for a variety of applications, this system is ideal for industries such as electric vehicles, renewable energy storage, and portable electronic devices, where batteries within the specified voltage and current ranges are commonly utilized.
Invest in our Battery Testing System for 30V60A 8 Channels to elevate your testing capabilities and ensure the reliability and performance of batteries in diverse applications.
Product Parameters
AC Input Parameters
Item |
Technical Parameters |
Wiring Method |
AC380V Three-Phase Five-Wire System |
Input Power Supply |
AC380V |
Power Factor |
≥99%(full load) |
THDi |
≤5%(full load) |
Maximum feedback efficiency |
≥92%(full load) |
DC output parameters
Item |
Technical Parameters |
Voltage range |
Charging Voltage: 0V ~ 30V Discharging Voltage: 6V ~ 30V |
Voltage Accuracy |
±0.05%FS |
Voltage Resolution |
1mV |
Current Range |
0 ~ 60A |
Current Accuracy |
±0.05%FS |
Current Resolution |
1mA |
Current Response Time |
10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time |
20ms(-90%FS ~ 90%FS) |
Channel Control Mode |
All channels can be independently controlled. |
Auxiliary channels |
Each channel is equipped with an auxiliary temperature channel. |
Step Function Features / Function Features of Operation Steps
Item |
Technical Parameters |
Minimum Data Logging Time |
10ms |
Editable Number of Steps |
2000 |
Number of Step Cycles |
65535 |
Step Cycle Nesting |
5 |
Charge and Discharge Modes |
Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria |
Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types |
Jump, Pause, Protect, Next Step |
Importing DBC Files |
Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) |
Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods |
Export data in Excel and CSV formats. |
Protection Functions
Item |
Technical Parameters |
AC-Side Protection |
AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection |
Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection |
Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating |
IP22 |
Operating Temperature Range |
0ºC~ 45ºC |
Cooling Method |
Forced Air Cooling |
Sound Level |
≤75dB |