Customization: | Available |
---|---|
After-sales Service: | Life-Time Sale Service |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing our "Reliable 60V60A Battery Pack Load Tester," a cutting-edge solution for comprehensive testing of battery modules and packs. This system is meticulously designed to conduct precise charge-discharge tests, capacity assessments, and more, ensuring accurate evaluation of battery performance.
Voltage and Current Precision:
Tailored for 60V60A battery packs, providing optimal performance and accuracy across a wide array of battery configurations.
Versatile Testing Modes:
This tester supports various testing modes, including constant current, constant voltage, pulse current, pulse power, and DC internal resistance. Its adaptability addresses diverse testing requirements.
Flexible Discharge Options:
Accommodates multiple discharge modes such as constant current, constant voltage, constant power, pulse current, and pulse power, offering flexibility for discharge testing.
Robust Protection Mechanisms:
Equipped with an extensive set of protection features, including short-circuit protection, overload protection, overvoltage protection, temperature alarms, capacity protection, and island protection.
Reliability in Performance Evaluation:
Ensures accurate and reliable performance evaluation of battery packs, providing insights into critical parameters such as voltage, current, and temperature.
Real-time Monitoring:
Operators can monitor real-time data during testing, offering immediate visibility into the performance characteristics of the battery pack under evaluation.
Comprehensive Data Logging:
The system captures detailed data throughout each testing cycle, facilitating thorough analysis of battery behavior for a comprehensive evaluation.
Applications:
Ideal for a broad spectrum of applications requiring a 60V60A power supply, our "Reliable 60V60A Battery Pack Load Tester" is indispensable for manufacturers, researchers, and engineers involved in the development and optimization of battery modules.
Operating Instructions:
Voltage and Current Configuration:
Set the desired voltage and current parameters to align with the specifications of the battery pack under evaluation.
Parameter Setup:
Utilize the user-friendly interface to configure specific test parameters, including charging rates, discharging parameters, and safety thresholds.
Initiate Testing:
Activate the testing process through the system interface, ensuring the proper connection of the battery pack to the tester.
Real-time Monitoring:
Monitor real-time data displayed on the interface during testing, providing valuable insights into each parameter's performance.
Data Analysis:
Review comprehensive data logs after testing completion, including voltage curves, current characteristics, and temperature variations, for a detailed analysis of battery performance.
AC Input Parameters
Item | Technical Parameters |
Wiring Method | AC380V Three-Phase Five-Wire System |
Input Power Supply | AC380V |
Power Factor | ≥99%(full load) |
THDi | ≤5%(full load) |
Maximum feedback efficiency | ≥92%(full load) |
Item | Technical Parameters |
Voltage range | Charging Voltage: 0V ~ 60V Discharging Voltage: 6V ~ 60V |
Voltage Accuracy | ±0.05%FS |
Voltage Resolution | 1mV |
Current Range | -60A ~ 60A |
Current Accuracy | ±0.05%FS |
Current Resolution | 1mA |
Current Response Time | 10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time | 20ms(-90%FS ~ 90%FS) |
Channel Control Mode | All channels can be independently controlled. |
Auxiliary channels | Each channel is equipped with an auxiliary temperature channel. |
Item | Technical Parameters |
Minimum Data Logging Time | 10ms |
Editable Number of Steps | 2000 |
Number of Step Cycles | 65535 |
Step Cycle Nesting | 5 |
Charge and Discharge Modes | Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria | Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types | Jump, Pause, Protect, Next Step |
Importing DBC Files | Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) | Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods | Export data in Excel and CSV formats. |
Item | Technical Parameters |
AC-Side Protection | AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection | Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection | Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating | IP22 |
Operating Temperature Range | 0ºC~ 45ºC |
Cooling Method | Forced Air Cooling |
Sound Level | ≤75dB |