Introducing our "60V 72A Battery Testing System Equipment for Lead Acid Battery Analysis." This sophisticated testing system is designed to cater to a wide range of battery modules and packs, offering precise charge-discharge testing, capacity detection, and more.
Voltage and Current Compatibility:
Tailored for 60V 72A lead-acid battery packs, ensuring optimal performance across a variety of battery configurations.
Multi-Functional Testing:
The system supports a diverse range of testing functions, including constant current, constant voltage, pulse current, pulse power, DC internal resistance. This versatility accommodates a broad spectrum of testing requirements.
Flexible Discharging Modes:
Accommodating various discharging modes such as constant current, constant voltage, constant power, pulse current, and pulse power, providing flexibility in discharge testing.
Advanced Protection Features:
Equipped with a robust set of protection mechanisms, including short-circuit protection, overload protection, overvoltage protection, temperature alarms, capacity protection, and island protection.
Real-time Monitoring:
Operators can monitor real-time data during the testing process, providing insights into voltage, current, and temperature parameters.
Data Logging and Analysis:
Comprehensive data logging captures detailed information throughout each testing cycle, facilitating in-depth analysis of battery module behavior.
Applications:
Tailored for various battery pack applications requiring a 60V 72A power supply, our "60V 72A Battery Testing System" is an essential tool for manufacturers, mechanics, and engineers involved in the development and optimization of lead-acid battery modules.
Operating Instructions:
Voltage and Current Configuration:
Set the desired voltage and current parameters to align with the specifications of the lead-acid battery pack under test.
Parameter Setup:
Utilize the user-friendly interface to configure specific test parameters, including charging rates, discharging parameters, and safety thresholds.
Initiate Testing:
Activate the testing process through the system interface, ensuring the proper connection of the lead-acid battery pack to the tester.
Real-time Monitoring:
Monitor real-time data displayed on the interface during testing. Detailed insights into each parameter's performance are readily available.
Data Analysis:
After testing completion, review comprehensive data logs, including voltage curves, current characteristics, and temperature variations. Analyze this data to assess the overall performance and health of the lead-acid battery pack.
AC Input Parameters
Item | Technical Parameters |
Wiring Method | AC380V Three-Phase Five-Wire System |
Input Power Supply | AC380V |
Power Factor | ≥99%(full load) |
THDi | ≤5%(full load) |
Maximum feedback efficiency | ≥92%(full load) |
Item | Technical Parameters |
Voltage range | Charging Voltage: 0V ~ 60V Discharging Voltage: 6V ~ 60V |
Voltage Accuracy | ±0.05%FS |
Voltage Resolution | 1mV |
Current Range | -100A ~ 100A |
Current Accuracy | ±0.05%FS |
Current Resolution | 1mA |
Current Response Time | 10ms(10%FS ~ 90%FS) |
Charge/Discharge Conversion Time | 20ms(-90%FS ~ 90%FS) |
Channel Control Mode | All channels can be independently controlled. |
Auxiliary channels | Each channel is equipped with an auxiliary temperature channel. |
Item | Technical Parameters |
Minimum Data Logging Time | 10ms |
Editable Number of Steps | 2000 |
Number of Step Cycles | 65535 |
Step Cycle Nesting | 5 |
Charge and Discharge Modes | Idle, Pause, Constant Current Charge (CC), Constant Voltage Charge (CV), Constant Resistance Charge (CR), Constant Current Constant Voltage Charge (CCCV), Constant Power Charge (CP), Constant Current Discharge (DC), Constant Power Discharge (DP), Constant Resistance Discharge (DR), Direct Current Internal Resistance Test (DCIR) |
Termination Criteria | Voltage, Current, Capacity, Energy, Time, Power, Cycle Count, BMS Parameters, Custom Advanced Parameters (Supporting Single or Multiple Logic AND/OR Combinations) |
Execution Action Types | Jump, Pause, Protect, Next Step |
Importing DBC Files | Supports File Editing, Saving, and Importing |
Direct Current Internal Resistance Testing (DCIR) | Supports DCIR (Direct Current Internal Resistance) test steps, hardware real-time calculation, and supports two types of tests: (V1-V2)/(I1-I2) and (V1-V2)/I. |
Data Export Methods | Export data in Excel and CSV formats. |
Item | Technical Parameters |
AC-Side Protection | AC Grid Voltage Over/Under Voltage Protection, Surge Protection, Anti-Islanding Protection, Over/Under Frequency Protection, Hardware Overtemperature Protection, Self-Test Protection, etc. |
DC-Side Protection | Bus Over/Under Voltage Protection, Hardware Overtemperature Protection, Battery Channel Line Reverse Connection Protection, etc. |
Battery-Side Comprehensive Protection | Battery pack total voltage upper/lower limit protection, battery cell voltage upper/lower limit protection, battery temperature upper/lower limit protection, battery charge/discharge current upper limit protection, battery capacity upper/lower limit protection, BMS communication loss protection, network disconnection protection, etc. |
Ingress Protection (IP) Rating | IP22 |
Operating Temperature Range | 0ºC~ 45ºC |
Cooling Method | Forced Air Cooling |
Sound Level | ≤75dB |